VolaTrap®

Breath research, within your grasp

Handheld Breath Sampler

Breath research,
within your grasp

Designed for use in basic and clinical research, this next-generation, handheld breath sampler—the first of its kind developed in Japan—ensures consistent, high-quality collection of volatile compounds (VCs) from exhaled breath, regardless of who performs the sampling or how the sample is transported.

Intended for analytical laboratories and medical and research institutions

VolaTrap Main Body

What is VolaTrap®

Upgrade your sampling workflow.

The VolaTrap® is a handheld breath sampler that can be operated with one hand. It collects volatile compounds (VCs) from exhaled breath simply by having the subject breathe naturally.

VCs can be collected directly in the sorbent tubes, which then integrate seamlessly into standard analytical workflows such as TD-GC-MS.

Features

Four reasons to choose VolaTrap®

01

High reproducibility

It collects a fixed volume of exhaled breath, minimizing data variability, regardless of who performs the collection or the facility where sampling takes place.

02

Stable storage and transport

Exhaled VCs are adsorbed onto collection tubes. This method minimizes degradation during transport—whether refrigerated or at room temperature—and is suitable for analysis by an external laboratory.

03

Ease of operation

Sample collection can be performed without special training. The single-use mouthpiece reduces the risk of cross-contamination.

04

Compatible with existing workflows

Existing sampling tubes and TD-GC-MS systems can be utilized, minimizing additional costs and workflow adjustments.

Workflow

Sample collection to analysis in 4 steps

01
Exhale into the mouthpiece and collect exhaled VCs.
Handled by VolaTrap®
02
VCs are adsorbed in the collection tubes.
Handled by VolaTrap®
03
Transported at room or refrigerated temperatures while maintaining product quality.
04
VC analysis by TD-GC-MS or similar workflows.

You can upgrade just the sampling workflow while continuing to use your existing analytical equipment.

About

Your breath analysis work is growing, but sample collection is a bottleneck.

Exhaled breath contains hundreds of types of volatile compounds (VCs), which are attracting attention as biomarkers for diseases. However, conventional collection methods have several limitations.

Issues

Three challenges that have plagued conventional breath sampling

Issue 01

Dependence on individual operator technique

The amount of exhaled breath collected varies from person to person, making it difficult to ensure data reproducibility.

Issue 02

The equipment is large-scale

Traditional on-line analytics are expensive and require a fixed installation, making them unsuitable for bedside use or multi-center deployment.

Issue 03

Sample degradation during storage and transport

Collected VCs are prone to volatilization and contamination, and their quality deteriorates during transport to external laboratories.

What you need —
Breath sample collection unaffected by transportation or who collects it.

VolaTrap Main Body

Product

What is the VolaTrap®?

It is Japan's first handheld breath sampler that can be operated with one hand. It collects volatile compounds in the breath of the subject simply by having them breathe naturally.

VCs can be collected directly into exhaled breath collection tubes and directly integrated into standard analytical flows such as TD-GC-MS. This allows you to upgrade your collection workflow specifically while utilizing your existing analytical equipment as-is.

Features

Four reasons to choose VolaTrap®

01

High reproducibility

It collects a fixed volume of exhaled breath, minimizing data variability, regardless of who performs the collection or the facility where sampling takes place.

02

Stable storage and transport

Exhaled VCs are adsorbed onto collection tubes. This method minimizes degradation during transport—whether refrigerated or at room temperature—and is suitable for analysis by an external laboratory.

03

Ease of operation

Sample collection can be performed without special training. The single-use mouthpiece reduces the risk of cross-contamination.

04

Compatible with existing workflows

Existing sampling tubes and TD-GC-MS systems can be utilized, minimizing additional costs and workflow adjustments.

Workflow

Sample collection to analysis in 4 steps

01
Exhale into the mouthpiece and collect exhaled VCs.
Handled by VolaTrap®
02
VCs are adsorbed in the collection tubes.
Handled by VolaTrap®
03
Transported at room or refrigerated temperatures while maintaining product quality
04
VC analysis by TD-GC-MS or similar workflows.

Comparison

Comparison with other available breath samplers

VolaTrap® offers both portability and reproducibility, providing a complete solution from consumables and cleaning to contract data acquisition.

VolaTrap® Company ACompany B
Collection methodHandheld - Selective capture of VCs in breathHandheld - Manual/End-tidalMask - Collection controlled by pump
Mouthpiece or maskSingle-use mouthpiece (also suitable for use with masks)Single-use mouthpieceSingle-use silicone mask
Breath fraction controlStable collection of breath onlyEnd-tidal (relies on operator skill)Gating of breath phase by pressure sensor
Power supply and purified air supplyNot required (portable)Not required (portable)Required(>30mL/min purified air)
Collection tubesDirect collection using standard collection tubesTransfer to the collection tube1 cartridge = direct collection to 4 tubes
ReproducibilityHigh (quantitative collection)Medium (relies on operator skill)High (Large, controlled equipment)
PortabilityVery portablVery portableStationary installation and power supply required
CostLow to MediumLowHigh
Available Consumables and Additional ServicesMouthpieces, filters, collection tube cleaning, contract data acquisition——

← Scroll →

*This is a general trend based on information released by each company. The VolaTrap® column shows a representative configuration; please refer to the latest instruction manual for confirmed specifications.

Catalogue

Product specifications

For more details, please see our product catalogue.

Company

Our information

Company Name
Tokai Denshi Inc. (Shizuoka, Japan)
Product Name
VolaTrap® (Handheld Breath Sampler)
Intended Audience
Research institutions, medical institutions, analytical laboratories (BtoB)
Contact Information
E-mail: medical_info@tokai-denshi.co.jp

FAQ

Frequently asked questions

We have compiled a list of frequently asked questions.
For questions not listed here, please feel free to contact us via the CONTACT page.

The VolaTrap® Breath Sampler

Is a power supply or purified air required?

No. The VolaTrap® is handheld and operates without a power supply or purified air. Therefore, it is portable and can be used in a variety of locations.

How uncomfortble or stressful is sample collection for the subjects?

This is a non-invasive sampling method that only requires exhaling into the device. No blood sampling or pre-treatment involved. Sampling can be completed without any special training.

How much do the results vary between operators?

Because the VolaTrap® collects a consistent volume of breath, variability is minimal, even if the person collecting the sample or the facility changes. This is a major difference from conventional sampling methods that vary depending on operator skill.

Analysis and Transportation

What types of analytical instruments are compatible?

It supports standard adsorption tubes (collection tubes) and thermal desorption workflows (analysis by TD-GC-MS). It can be implemented with minimal investment in new equipment.

How should the collected samples be transported?

Since exhaled VCs are adsorbed onto the collection tubes, degradation can be minimized even during refrigerated or ambient temperature transport. Operation is possible even when sending samples to external laboratories.

Will environmental VCs also be collected in the sample?

The inlet filter reduces contamination from the external environment. Furthermore, the single-use mouthpiece minimizes the risk of cross-contamination between subjects.

Implementation and Transactions

Can I get a quote and discuss delivery dates?

We will provide a quote based on the quantity and specifications of your inquiry, as well as your location. Please also let us know your circumstances, such as the schedule for the expenditure of research funds.

Would it be possible to discuss collaborative research?

Yes! We will propose an arrangement that includes equipment configuration, consumables, and analysis, tailored to your application field and research stage. Please contact us via the CONTACT page for more information.

Contact

Contact us!

Please feel free to contact us for quotes, joint research inquiries, and other inquiries.


Please include the following information, as relevant:
  • Your affiliation (organization name/department name) and your name
  • Inquiry details (product specifications, collaborative research proposals, contract analysis, etc.)
  • What analytical equipment do you plan to use, and what is your intended use?

This site is intended for product presentation purposes; no online sales are conducted here.