Handheld Breath Sampler
Breath research,
within your grasp
Designed for use in basic and clinical research, this next-generation, handheld breath sampler—the first of its kind developed in Japan—ensures consistent, high-quality collection of volatile compounds (VCs) from exhaled breath, regardless of who performs the sampling or how the sample is transported.

What is VolaTrap®
Upgrade your sampling workflow.
The VolaTrap® is a handheld breath sampler that can be operated with one hand. It collects volatile compounds (VCs) from exhaled breath simply by having the subject breathe naturally.
VCs can be collected directly in the sorbent tubes, which then integrate seamlessly into standard analytical workflows such as TD-GC-MS.
Features
Four reasons to choose VolaTrap®
High reproducibility
It collects a fixed volume of exhaled breath, minimizing data variability, regardless of who performs the collection or the facility where sampling takes place.
Stable storage and transport
Exhaled VCs are adsorbed onto collection tubes. This method minimizes degradation during transport—whether refrigerated or at room temperature—and is suitable for analysis by an external laboratory.
Ease of operation
Sample collection can be performed without special training. The single-use mouthpiece reduces the risk of cross-contamination.
Compatible with existing workflows
Existing sampling tubes and TD-GC-MS systems can be utilized, minimizing additional costs and workflow adjustments.
Workflow
Sample collection to analysis in 4 steps
You can upgrade just the sampling workflow while continuing to use your existing analytical equipment.
About
Your breath analysis work is growing, but sample collection is a bottleneck.
Exhaled breath contains hundreds of types of volatile compounds (VCs), which are attracting attention as biomarkers for diseases. However, conventional collection methods have several limitations.
Issues
Three challenges that have plagued conventional breath sampling
Dependence on individual operator technique
The amount of exhaled breath collected varies from person to person, making it difficult to ensure data reproducibility.
The equipment is large-scale
Traditional on-line analytics are expensive and require a fixed installation, making them unsuitable for bedside use or multi-center deployment.
Sample degradation during storage and transport
Collected VCs are prone to volatilization and contamination, and their quality deteriorates during transport to external laboratories.
What you need —
Breath sample collection unaffected by transportation or who collects it.

Product
What is the VolaTrap®?
It is Japan's first handheld breath sampler that can be operated with one hand. It collects volatile compounds in the breath of the subject simply by having them breathe naturally.
VCs can be collected directly into exhaled breath collection tubes and directly integrated into standard analytical flows such as TD-GC-MS. This allows you to upgrade your collection workflow specifically while utilizing your existing analytical equipment as-is.
Features
Four reasons to choose VolaTrap®
High reproducibility
It collects a fixed volume of exhaled breath, minimizing data variability, regardless of who performs the collection or the facility where sampling takes place.
Stable storage and transport
Exhaled VCs are adsorbed onto collection tubes. This method minimizes degradation during transport—whether refrigerated or at room temperature—and is suitable for analysis by an external laboratory.
Ease of operation
Sample collection can be performed without special training. The single-use mouthpiece reduces the risk of cross-contamination.
Compatible with existing workflows
Existing sampling tubes and TD-GC-MS systems can be utilized, minimizing additional costs and workflow adjustments.
Workflow
Sample collection to analysis in 4 steps
Comparison
Comparison with other available breath samplers
VolaTrap® offers both portability and reproducibility, providing a complete solution from consumables and cleaning to contract data acquisition.
| VolaTrap® | Company A | Company B | |
|---|---|---|---|
| Collection method | Handheld - Selective capture of VCs in breath | Handheld - Manual/End-tidal | Mask - Collection controlled by pump |
| Mouthpiece or mask | Single-use mouthpiece (also suitable for use with masks) | Single-use mouthpiece | Single-use silicone mask |
| Breath fraction control | Stable collection of breath only | End-tidal (relies on operator skill) | Gating of breath phase by pressure sensor |
| Power supply and purified air supply | Not required (portable) | Not required (portable) | Required(>30mL/min purified air) |
| Collection tubes | Direct collection using standard collection tubes | Transfer to the collection tube | 1 cartridge = direct collection to 4 tubes |
| Reproducibility | High (quantitative collection) | Medium (relies on operator skill) | High (Large, controlled equipment) |
| Portability | Very portabl | Very portable | Stationary installation and power supply required |
| Cost | Low to Medium | Low | High |
| Available Consumables and Additional Services | Mouthpieces, filters, collection tube cleaning, contract data acquisition | — | — |
← Scroll →
*This is a general trend based on information released by each company. The VolaTrap® column shows a representative configuration; please refer to the latest instruction manual for confirmed specifications.
Catalogue
Product specifications
For more details, please see our product catalogue.
Company
Our information
- Company Name
- Tokai Denshi Inc. (Shizuoka, Japan)
- Product Name
- VolaTrap® (Handheld Breath Sampler)
- Intended Audience
- Research institutions, medical institutions, analytical laboratories (BtoB)
- Contact Information
- E-mail: medical_info@tokai-denshi.co.jp
FAQ
Frequently asked questions
We have compiled a list of frequently asked questions.
For questions not listed here, please feel free to contact us via the CONTACT page.
The VolaTrap® Breath Sampler
Is a power supply or purified air required?
No. The VolaTrap® is handheld and operates without a power supply or purified air. Therefore, it is portable and can be used in a variety of locations.
How uncomfortble or stressful is sample collection for the subjects?
This is a non-invasive sampling method that only requires exhaling into the device. No blood sampling or pre-treatment involved. Sampling can be completed without any special training.
How much do the results vary between operators?
Because the VolaTrap® collects a consistent volume of breath, variability is minimal, even if the person collecting the sample or the facility changes. This is a major difference from conventional sampling methods that vary depending on operator skill.
Analysis and Transportation
What types of analytical instruments are compatible?
It supports standard adsorption tubes (collection tubes) and thermal desorption workflows (analysis by TD-GC-MS). It can be implemented with minimal investment in new equipment.
How should the collected samples be transported?
Since exhaled VCs are adsorbed onto the collection tubes, degradation can be minimized even during refrigerated or ambient temperature transport. Operation is possible even when sending samples to external laboratories.
Will environmental VCs also be collected in the sample?
The inlet filter reduces contamination from the external environment. Furthermore, the single-use mouthpiece minimizes the risk of cross-contamination between subjects.
Implementation and Transactions
Can I get a quote and discuss delivery dates?
We will provide a quote based on the quantity and specifications of your inquiry, as well as your location. Please also let us know your circumstances, such as the schedule for the expenditure of research funds.
Would it be possible to discuss collaborative research?
Yes! We will propose an arrangement that includes equipment configuration, consumables, and analysis, tailored to your application field and research stage. Please contact us via the CONTACT page for more information.
Contact
Contact us!
Please feel free to contact us for quotes, joint research inquiries, and other inquiries.
Please include the following information, as relevant:
- Your affiliation (organization name/department name) and your name
- Inquiry details (product specifications, collaborative research proposals, contract analysis, etc.)
- What analytical equipment do you plan to use, and what is your intended use?
This site is intended for product presentation purposes; no online sales are conducted here.